High-Efficiency Semi-Hermetic Centrifugal Chiller
19XR Single-Stage (200 to 1600 tons)
–Constant Speed
–Variable Speed (19XRV)
19XR Two-Stage (600 to 3,400 tons)
–Constant Speed
–Variable Speed (19XRV)
19XRD Dual Circuit (2500 to 3000 tons)
The AquaEdge™ 19XR/XRV/XRD centrifugal chillers achieve energy efficiency levels using proven technology designed specifically for chlorine-free refrigerant. This combination ensures the most cost-effective, reliable solution for today’s comfort cooling and process cooling applications.
Carrier’s AquaEdge™ chillers offer the best value in high-efficiency, chlorine-free centrifugal HVAC chillers.
Options
Factory-Installed Options
- Enhanced tubing, .028 or .035 in. (0.711 or 0.889 mm):
- Internally/externally enhanced copper tubing – cooler/condenser
- Internally/externally enhanced cupronickel tubing – condenser
- Smooth bore/externally enhanced copper tubing – cooler/condenser
- Smooth bore/externally enhanced cupronickel tubing – condenser
- Wall tubes, titanium, condenser, .025 or .028 in. (0.635 or 0.711 mm):
- Internally enhanced tubes
- Marine waterboxes
- 150 psig (1034 kPa) waterbox
- 300 psig (2068 kPa) waterbox, ASME certified
- Marine bolt-on waterboxes for condenser, 150 psig (1034 kPa) with titanium clad tubesheets (available on condenser frame sizes 2 to 8 only)
- Nozzle-in-head waterbox, 300 psig (2068 kPa)
- Flanged cooler and/or condenser waterbox nozzles
- Waterbox hinges
- Unit-mounted, low-voltage wye-delta or solid-state starters (Heat exchanger frames 1-7 only)
- One, 2, or 3 pass cooler or condenser waterside construction
- Zinc anodes
- BACnet® Communications
- Refrigerant isolation valves
- Shipped factory charged with refrigerant
- Unit-mounted pumpout unit
- Hot gas bypass
- Unit-mounted refrigerant-cooled variable frequency drive
- Thermal insulation (except waterbox covers)
- Customer factory performance testing
- Export crating
- Discharge line sound reduction kit
- Seismic Kit
- Extended Warranty (North America only)
- Service Contract
Field-Installed Accessories
- BACnet® Carrier Translator
- LonWorks® Carrier translator
- Sensor package
- Separate storage tank and pumpout unit
- Stand-alone pumpout unit
- Soleplate package
- Spring isolator kit
- Acoustical sound insulation kit
- Freestanding Low Voltage Wye-Delta & Solid Starters
- Freestanding Low Voltage Variable Frequency Drives
- Freestanding Medium Voltage Variable Frequency Drives
Physical Data
Heat
exchanger
size† |
Length with
nozzle-in-head waterbox |
Width |
Height ** |
2-Pass* |
1 or 3-Pass |
ft-in. |
mm |
ft-in. |
mm |
ft-in. |
mm |
ft-in. |
mm |
10 to 12 |
11-4 |
3454 |
11-11 |
3632 |
5-2 7/8 |
1597 |
6-1 1/4 |
1861 |
15 to 17 |
13-7 1/2 |
4153 |
14-2 1/2 |
4331 |
5-2 7/8 |
1597 |
6-1 1/4 |
1861 |
20 to 22 |
11-4 3/4 |
3473 |
11-11 3/4 |
3651 |
5-6 7/8 |
1688 |
6-3 1/4 |
1911 |
30 to 32 |
13-8 1/4 |
4172 |
14-3 1/4 |
4350 |
5-6 7/16 |
1688 |
6-3 1/4 |
1911 |
35 to 37 |
15-4 3/4 |
4693 |
15-11 3/4 |
4870 |
5-6 7/16 |
1688 |
6-3 1/4 |
1911 |
40 to 42 |
14-3 1/8 |
4347 |
14-9 |
4496 |
6-3 1/8 |
1908 |
7-0 3/4 |
2153 |
45 to 47 |
15-8 5/8 |
4867 |
16-5 1/2 |
5017 |
6-3 1/8 |
1908 |
7-0 3/4 |
2153 |
50 to 54, 5K to 5R |
14-4 1/2 |
4382 |
14-10 |
4521 |
6-6 1/2 |
1994 |
7-1 |
2159 |
5A to 5C |
14-4 1/2 |
4382 |
14-10 |
4521 |
6-6 1/2 |
1994 |
7-1 |
2159 |
55 to 59, 5T to 5Z |
16-1 |
4902 |
16-6 1/2 |
5042 |
6-6 1/2 |
1994 |
7-1 |
2159 |
5F to 5H |
16-1 |
4902 |
16-6 1/2 |
5042 |
6-6 1/2 |
1994 |
7-1 |
2159 |
60 to 64, 6K to 6R |
14-5 1/4 |
4401 |
14-11 |
4547 |
6-11 5/8 |
2124 |
7-4 7/8 |
2257 |
65 to 69, 6T to 6Z |
16-1 3/4 |
4921 |
16-7 1/2 |
5067 |
6-11 5/8 |
2124 |
7-4 7/8 |
2257 |
70 to 74, 7K to 7R |
16-6 1/8 |
5032 |
17-0 1/2 |
5194 |
8-1 1/4 |
2470 |
9-9 1/2 |
2985 |
75 to 79, 7T to 7Z |
18-6 1/8 |
5642 |
19-0 1/2 |
5804 |
8-1 1/4 |
2470 |
9-9 1/2 |
2985 |
80 to 84, 8K to 8R |
16-9 1/8 |
5109 |
17-3 1/2 |
5271 |
8-10 3/4 |
2711 |
9-11 1/4 |
3029 |
85 to 89, 8T to 8Z |
18-9 1/8 |
5718 |
19-3 1/2 |
5880 |
8-10 3/4 |
2711 |
9-11 1/4 |
3029 |
*Assumes all customer connections are on the same end of the chiller.
**Height is for chiller without unit-mounted starter.
†Heat exchangers are rated for typical applications at ARI Conditions (44F leaving chilled water and 2.4 gpm/ton in the cooler, and 85F entering condenser water with 3.0 gpm/ton flow in the condenser).